NICE5000 User Manual 6 Function Code Table
- 99 -
Function
Code Group
Type
Function
Code Group
Type
Function
Code Group
Type
F2
Vector control
parameters
FA
Auxiliary
parameters
FU
Monitoring
parameters
F3
Running control
parameters
Fb
Door function
parameters
FF
Factory parameters
F4
Floor
parameters
FC
Brief fault
information
FP
User parameters
F5
Terminal
function
parameters
Fd
Parallel control
parameters
E0 to E9
Fault details
F6
Elevator logic
parameters
FE
Display
parameters
F7
Intelligent
commissioning
parameters
FH
Close-loop
parameters
6.3 Function Code Table
Function
Code
Parameter Name Setting Range Default
Unit
Property
Group F0: Basic parameters
F0-00
Control mode
0: Sensorless vector control
(SVC)
1: Closed-loop vector control
(CLVC)
2: Voltage/Frequency (V/F) control
1
-
★
F0-01
Command source
selection
0: Operation panel control
1: Distance control
1
-
★
F0-02
Running speed
under operation
panel control
0.050 to F0-04
0.050
m/s
☆
F0-03
Maximum running
speed
0.100 to F0-04
1.600
m/s
★
F0-04
Rated elevator
speed
0.100–4.000
1.600
m/s
★
F0-05
Elevator running
direction
0–1
0
-
★
F0-07
Carrier frequency 2.0–16.0
8.0
kHz
★
Group F1: Motor parameters
F1-00
Group F1 security
password
0–65535
01000
-
★
F1-01
Rated motor power 1.1–132.0
Model
dependent
kW
★