EasyManuals Logo

Monarch NICE 5000 User Manual

Monarch NICE 5000
233 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #118 background imageLoading...
Page #118 background image
6 Function Code Table NICE5000 User Manual
- 116 -
Function
Code
Parameter Name Setting Range Default
Unit
Property
F9-02
Motor running time
limit
0–45
45
s
F9-03
Accumulative
working hours
0–65535
0
h
F9-04
Accumulative
running hours
0–65535
0
h
F9-05
Accumulative
working days
0–65535
0
day
F9-06
High byte of
running times
0–9999
0
-
F9-07
Low byte or
running times
0–9999
0
-
F9-12
Clock: year 2000–2100
2010
YYYY
F9-13
Clock: month and
day
1.01–12.31
301
MM.DD
F9-14
Clock: hour and
minute
0–23.59
0
HH.MM
Group FA: Auxiliary parameters
FA-00
Group FA security
password
0–65535
01000
-
FA-01
Display in running
state
1–65535
65535
-
FA-02
Display in stop
state
1–65535
4095
-
FA-03
Product SN 1–7000
5000
-
FA-04
Software version 1
(CTB)
0–65535
0
-
FA-05
Software version 2
(MCB)
0–65535
0
-
FA-06
Software version
3 (drive board
software)
0–65535
0
-
FA-07
Heatsink
temperature
0–100
0
°C
FA-09
Protection function
selection
Bit0: Overload protection
Bit1: Output phase loss protection
Bit3: Input phase loss protection
3
-
FA-10
Overload
protection
coefcient
0.50–10.00
1.00
-
FA-11
Overload pre-
warning coefcient
50–100
80
%

Table of Contents