NICE5000 User Manual 6 Function Code Table
- 115 -
Function
Code
Parameter Name Setting Range Default
Unit
Property
F8-01
Pre-torque
selection
0: Invalid
1: Valid
0
-
★
F8-02
Pre-torque offset 0.0–100.0
50.0
%
★
F8-03
Drive gain 0.00–2.00
0.60
-
★
F8-04
Brake gain 0.00–2.00
0.60
-
★
F8-05
Load cell data 0–255
0
-
●
F8-06
No-load load
threshold
0–255
0
-
★
F8-07
Full-load load
threshold
0–255
100
-
★
F8-08
Anti-nuisance
function
0: Anti-nuisance function disabled
1: Nuisance judged by load cell
2: Nuisance judged by light
curtain
4: Nuisance judged by light-load
signal
0
-
☆
F8-09
Rated elevator load 300–9999
1000
kg
★
F8-10
Logic program
control
Bit13: Hiding uncommon
parameters
0
-
★
F8-14
Local address
0–127
0: broadcast address
1
-
★
F8-18
Overload
percentage
100–130
110
%
★
F8-19
Full-load
percentage
70–110
80
%
★
F8-20
Light-load
percentage
10–50
30
%
★
F8-21
Arrival gong
advance time
0–10.0
1.0
s
★
F8-22
Delay upon door
open limit
0–2000
1000
ms
★
F8-24
Command 2 start
address
0–56
0
-
★
Group F9: Time parameters
F9-00
Idle time before
returning to base
oor
0–240
10
min
★
F9-01
Time for fan and
lamp to be turned
off
0–240
2
min
★