6 Function Code Table NICE5000 User Manual
- 114 -
Function
Code
Parameter Name Setting Range Default
Unit
Property
F6-49
Service oors 1 of
time-based oor
service 3
0–65535
65535
-
F6-50
Service oors 2 of
time-based oor
service 3
0–65535
65535
-
F6-51
Service oors 3 of
time-based oor
service 3
0–65535
65535
-
F6-52
Service oors 4 of
time-based oor
service 3
0–65535
65535
-
Group F7: Intelligent commissioning parameters
F7-00
Car call oor
registered
0 to F6-00
0
-
F7-01
Up call oor
registered
0 to F6-00
0
-
F7-02
Down call oor
registered
0 to F6-00
0
-
F7-03
Random running
times
0–60000
0
-
F7-04
Hall call enabled
0: Yes
1: No
0
-
F7-05
Door open enabled
0: Yes
1: No
0
-
F7-06
Overload function
0: Disabled
1: Enabled
0
-
F7-07
Limit switch
0: Enabled
1: Disabled
0
-
F7-08
Time interval of
random running
0–1000
0
s
F7-09
Accumulative
energy
consumption
0–65535
0
kW
F7-10
Accumulative
feedback energy
0–65535
0
kW
F7-26
Commissioning
function selection
0: No operation
1: Shaft auto-tuning
0
-
Group F8: Auxiliary logic parameters
F8-00
Load for load cell
auto-tuning
0–100
0
%

Table of Contents