6 Function Code Table NICE5000 User Manual
- 118 -
Function
Code
Parameter Name Setting Range Default
Unit
Property
Fb-14
Door state of
standby elevator
0: Closing the door as normal at
base oor
1: Waiting with door open at base
oor
2: Waiting with door open at each
oor
0
-
Fb-15
Door open holding
time for hall call
1–30
5
s
Fb-16
Door open holding
time for car call
1–30
3
s
Fb-17
Door open holding
time at base oor
1–30
10
s
Fb-18
Door open delay 10–30000
30
s
Fb-19
Special door open
holding time
10–1000
30
s
Fb-20
Manual door open
holding time
1–60
10
s
Group FC: Brief fault information
FC-00
Designated fault 0–99
0
-
FC-01
20th fault code 0–6299
0
-
FC-02
20th fault subcode 0–65535
0
-
FC-03
20th fault month
and day
0–1231
0
MM.DD
FC-04
20th fault hour and
minute
0–2359
0
HH.MM
FC-05
20th fault
information
0–65535
0
-
FC-06
19th fault code 0–6299
0
-
FC-07
19th fault subcode 0–65535
0
-
FC-08
19th fault month
and day
0–1231
0
MM.DD
FC-09
19th fault hour and
minute
0–2359
0
HH.MM
FC-10
19th fault
information
0–65535
0
-
FC-11
18th fault code 0–6299
0
-
FC-12
18th fault subcode 0–65535
0
-
FC-13
18th fault month
and day
0–1231
0
MM.DD
FC-14
18th fault hour and
minute
0–2359
0
HH.MM

Table of Contents