NICE5000 User Manual 7 Description of Function Codes
- 161 -
Bit Function Description Default
Bit6
Shorting stator
braking mode
switched over to
controller drive
It enables the function of switching over shorting stator
braking mode to controller drive.
0
Bit7
Mode of shorting
stator braking
mode switched
over to controller
drive
0
If the time of the shorting stator braking mode exceeds
30s, the controller starts to drive the elevator.
0
1
If the speed is still smaller than 0.005 m/s after 3s in
the shorting stator braking mode, the controller starts
to drive the elevator.
Bit8
Emergency
evacuation exit
mode
0
The system exits emergency evacuation when
receiving the door open limit signal from the elevator
that arrives at the destination oor.
0
1
The system exits emergency evacuation when
receiving the door close limit signal from the elevator
that arrives at the destination oor.
Function Code Parameter Name Setting Range Default Unit Property
F6-28
Inspection function selection 0–65535
33 -
It is used to select the inspection-related functions. Each bit of the function code denes a
function, as described in the following table.
If a bit is set to 1, the function indicated by this bit is enabled; if this bit is set to 0, the
function is disabled.
The functions dened by the binary bits are described in the following table.
Bit Function Description Default
Bit0
Fire emergency prompt
in inspection state
If the re emergency signal is active in inspection
state, the controller outputs the arrival gong at
intervals, giving a prompt to the inspection operator.
1
Bit1
Door lock disconnected
after inspection switched
over to normal running
The door lock is additionally disconnected once
when the inspection state is switched over to the
normal running state.
0
Bit2 to
Bit4
Reserved
- 0
Bit5
Door open and close
once after inspection
turned to normal or rst-
time power-on
The elevator door opens and closes once after the
system turns from inspection to normal running or
during rst-time power-on.
1
Function Code Parameter Name Setting Range Default Unit Property
F6-30 VIP function selection 0–65535 0 -
It is used to select the elevator VIP function. Each bit of the function code denes a function,
as described in the following table.