7 Description of Function Codes NICE5000 User Manual
- 162 -
If a bit is set to 1, the function indicated by this bit is enabled; if this bit is set to 0, the
function is disabled.
The functions dened by the binary bits are described in the following table.
Bit Function Description Default
Bit0
VIP1 function
If this function is enabled, the system enters VIP running
when the VIP input is active and F6-31 is a non-zero
value.
1
Bit1
VIP2 function
If this function is enabled (function in Bit7 is disabled),
the system enters VIP running when the security input is
active and F6-32 is a non-zero value.
0
Bit2
VIP enabled by hall
call (at VIP oor)
When there is a hall call at the VIP oor, the system
enters VIP running.
If there are hall calls at both VIP oor 1 and VIP oor 2,
the system responds to the hall call at VIP oor 2 rst.
0
Bit3
VIP enabled by
button at VIP oor
If you hold down the door open button for 3s upon door
open limit after the elevator arrives at the VIP oor, the
system enters VIP running.
0
Bit4
VIP enabled by
terminal
After the terminal for VIP hall call becomes ON, the
system enters VIP running.
0
Bit5
VIP enabled by
button at any oor
If you hold down the door open button for 3s upon door
open limit after the elevator arrives at any oor, the
system enters VIP running.
0
Bit6
VIP enabled by car
call
When there is a car call at the VIP oor, the system
enters VIP running and does not respond to hall calls.
0
Bit7
Security oor auto
enable
If this function is enabled, VIP oor 2 set in F6-32 is used
as the security oor during 22:00 to 6:00. The elevator
runs to the security oor rst every time, stops and opens
the door, and then runs to the destination oor.
0
Bit8
Number of VIP car
calls limited
If this function is enabled, only one car call can be
selected simultaneously in the VIP state.
0
Bit9
VIP auto exit
If this function is enabled, the system exits VIP running
after the VIP auto exit time set in F6-33 is reached.
0
Bit10
to
Bit13
Reserved
- 0
Bit13
Hall call saved
During VIP running, the system saves the hall call but
does not respond to it.
0
Bit14
Auto door close
If this function is enabled, the elevator automatically
closes the door after the door open holding time is
reached.
If this function is disabled, door close is implemented by
pressing the door close button.
1
Bit15
Reserved
- 0
Function Code Parameter Name Setting Range Default Unit Property
F6-31
VIP oor 1 0 to F6-00
0 - ★