NICE5000 User Manual 7 Description of Function Codes
- 195 -
Function Code Parameter Name Setting Range Default Unit Property
FU-32
Nearest landing oor 1–56
0 - ●
FU-33
Destination oor 1–56
0 - ●
These parameters display the nearest oor that the elevator can land and the destination
oor.
Function Code Parameter Name Setting Range Default Unit Property
FU-34
Stop time 0.0–60.0
0 s ●
It displays the time required for this running. "60" is displayed at stop.
Function Code Parameter Name Setting Range Default Unit Property
FU-35
Deceleration distance 0.0–100.0
0 s ●
It displays the deceleration distance from the rated elevator speed to zero speed under the
current setting of deceleration parameters (deceleration speed and time).
Function Code Parameter Name Setting Range Default Unit Property
FU-49 Mod1 communication state 1 0–65535 0 - ●
FU-50 Mod1 communication state2 0–65535 0 - ●
FU-51 Mod1 communication state 3 0–65535 0 - ●
FU-52 Mod1 communication state 4 0–65535 0 - ●
These parameter display the Mod1 communication state between the HCB of all oors and
the MCB.
Each parameter specify different oor addresses:
•
State 1: oors 1–16
•
State 2: oors 17–32
•
State 3: oors 33–48
•
State 4: oors 49–56
Figure 7-11 Viewing Mod1 communication state between HCBs and MCB
12345
Present address
Communication
state of present
address
Address of the
HCB at each floor
Segment ON: communication normal
Segment OFF: communication abnormal
Display
Meaning
1
0
Normal Interrupted