3-86 Customer Programming Software (CPS)
6866588D21-D Chapter 3 - MTP850 Ex/MTP810 Ex Product Information Manual March 2009
20.4.2 Type Order
Indicates the sequence in which the call types appear to the user when the user presses the ‘Call
Type’ soft key.
To change the setting, select the field value, then select the desired option.
Related fields:
For the Private call, one of the Private Call features needs to be enabled: half-duplex or full-duplex,
& Paragraph 14.14 "Talkgroup Scan"
For the Phone and PABX Call, the corresponding feature needs to be enabled, Paragraph 14.8
"Telephone Interconnect" & Paragraph 14.14 "Talkgroup Scan"
20.5 Signal/Quality Indication Scale
These two fields are used for setting the number of bars that will be displayed to represent received
signal strength.
20.5.1 Signal Strength Maximum Nobars
TMO/DMO dependent.
This field defines the maximum number of bars that will be displayed to indicate the QUALITY of the
received signal in TMO, the bars are displayed to the left of the ‘mast’ icon and if the terminal looses
coverage a warning is displayed and an alert sounded.
This field also defines the number of bars that will be displayed to indicate the STRENGTH of the
received signal in DMO, the bars are displayed without the mast icon.
The range is from 0 - 127, the default being 9.
20.5.2 Signal Strength Minimum Maxbars
This field defines the minimum number of bars that will be displayed to indicate the quality/strength
of the received signal. These bars are displayed to the right of the ‘mast’ received signal strength
icon.
The range is from 0 - 127, the default being 35.