3-100 Customer Programming Software (CPS)
6866588D21-D Chapter 3 - MTP850 Ex/MTP810 Ex Product Information Manual March 2009
24.1.1.3 Transmission Time Out Timer
The entry in this field is the per range allowed call talk time. The time range is from 0 to 300
seconds.
24.1.1.4 Transmission time Out Warning Timer
Parameter controlling, per range, the time for generating <TOT Warning Tone> prior to <TOT>
expires. The <TOT warning tone timer> shall be less than <TOT> setting.
The radio can continuously transmit until the <TOT Warning Tone timer> expired, then the phone
will generate <TOT Warning Tone> to alert the user that transmission will soon be stopped.
The time can be set between 0 - 299 seconds.
24.1.1.5 Number of Talkgroups in Range
This field value is used to define the number of available Talkgroup entries for an individual range
and is programmable from 0 to 2048, in other words there can be one range list with 2048 entries, or
256 ranges each with 8 Talkgroup entries.
24.1.1.6 Receive Only
This is a per range setting and if the check box is selected, the user will be able to hear the calls, but
will not able to set up group calls to any of the talkgroups in the range, or PTT when listening to a
call.
Related fields are:
Paragraph 18.3 "Scanning Parameters"
Paragraph 24.1.4 "TMO Scan Lists"
24.1.2 TMO Talkgroup List
Note: At least one entry field must remain empty if DGNA is to be used, see Chapter 2 of the
Product Information Manual, Paragraph "Dynamic Group Number Assignment (DGNA)".
24.1.2.1 Name
This field can be programmed with up to 12 alphanumeric digits for the name/alias of the group.
24.1.2.2 ID
This is a Group Short Subscriber Identity (GSSI) of up to 8 digits and in the range 0 to 15,999,999
can be entered in this field to define the identity of the group.
Note: The same group(s) can be added to several/all ranges as required.