Device Name
Setting
Description
Factory Default
1 to 255 characters
Enter a name for the device. This is useful for differentiating
between the roles or applications of different units. Note that
the device name cannot be empty and must comply with the
following naming rules:
Only supports letters (a-z), numbers (0-9), and special
character dash (-)
Cannot contain any spaces
Cannot start with dash (-)
Cannot end with dash (-)
When used in a PROFINET environment, cannot start with
the prefix "port-x" where "x" equals 0 to 9. There is no
validity check to identify incorrect name formats.
Moxa-awk-3252a
Time
Clock Source
Setting
Description
Factory Default
Sync From Browser
Synchronize the system clock with the browser’s clock.
Sync From Browser
NTP
Set the clock source to NTP. This will sync the system clock
with an external NTP server.
Time Server 1 (for Clock Source is NTP)
Setting
Description
Factory Default
NTP time server
Specify the IP or domain address of the primary NTP server to
use (e.g., 192.168.1.1, time.stdtime.gov.tw, or
time.nist.gov).
None
Time Server 2 (for Clock Source is NTP)
Setting
Description
Factory Default
NTP time server
Specify the IP or domain address of the secondary NTP server.
The secondary NTP server acts as a backup in case the device
fails to connect to the first NTP server.
None
Time Zone
Setting
Description
Factory Default
Time zone
Select a time zone.
UTC+00:00
Daylight Saving Time Status
Setting
Description
Factory Default
Enabled/Disabled
Enable or disable Daylight Saving Time.
Disabled
Offset
Setting
Description
Factory Default
User-specified value
Specify the offset value for Daylight Saving Time.
00:00
Start
Setting
Description
Factory Default
User-specified date
Specify the date that Daylight Saving Time begins.
None
End
Setting
Description
Factory Default
User-specified date
Specify the date that Daylight Saving Time ends.
None
IP Configuration
IP Mode
Setting
Description
Factory Default
DHCP
The AWK is assigned an IP address automatically by the
network’s DHCP server.
Static
Static
Manually configure up the AWK’s IP address.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Moxa Technologies AWK Series and is the answer not in the manual?

Moxa Technologies AWK Series Specifications

General IconGeneral
BrandMoxa Technologies
ModelAWK Series
CategoryNetwork Hardware
LanguageEnglish

Related product manuals