Device Name
1 to 255 characters
Enter a name for the device. This is useful for differentiating
between the roles or applications of different units. Note that
the device name cannot be empty and must comply with the
following naming rules:
• Only supports letters (a-z), numbers (0-9), and special
character dash (-)
• Cannot contain any spaces
• Cannot start with dash (-)
• Cannot end with dash (-)
• When used in a PROFINET environment, cannot start with
the prefix "port-x" where "x" equals 0 to 9. There is no
validity check to identify incorrect name formats.
Moxa-awk-3252a
Time
Clock Source
Synchronize the system clock with the browser’s clock.
Sync From Browser
NTP
Set the clock source to NTP. This will sync the system clock
with an external NTP server.
Time Server 1 (for Clock Source is NTP)
NTP time server
Specify the IP or domain address of the primary NTP server to
use (e.g., 192.168.1.1, time.stdtime.gov.tw, or
None
Time Server 2 (for Clock Source is NTP)
NTP time server
Specify the IP or domain address of the secondary NTP server.
The secondary NTP server acts as a backup in case the device
fails to connect to the first NTP server.
None
Time Zone
Daylight Saving Time Status
Enable or disable Daylight Saving Time.
Offset
Specify the offset value for Daylight Saving Time.
Start
Specify the date that Daylight Saving Time begins.
End
Specify the date that Daylight Saving Time ends.
IP Configuration
IP Mode
DHCP
The AWK is assigned an IP address automatically by the
network’s DHCP server.
Static
Manually configure up the AWK’s IP address.