120 Part Number STH034 3/12
REACH-IN TEMPERATURE OUT OF RANGE -
CHECK REFRIGERATION SYSTEM AND DOOR
SEAL.
Temperature in reach-in unit above or below
acceptable limits.
Above temperature limit:
Verify door is closed and door gasket is in place.
Reboot machine by moving toggle switch off/on.
Allow refrigeration system to run for 15 minutes
and recheck temperature.
Refer to Refrigeration diagnostics.
Below temperature limit:
Check temperature setpoint.
Check thermistor.
Check compressor relay on relay circuit board.
HIGH PRODUCT TEMPERATURE - CHECK DUCT
COOLING FAN
Product temperature is greater than 42 F.
Verify the door was not left open or warm product
was added.
Reboot machine by moving toggle switch off/on.
Verify duct fan is operating.
Allow machine to run for 15 minutes then prime
each product.
If fault remains check duct temperature with a
digital thermometer to determine if refrigeration or
thermistor diagnostics need to be performed.