72 Part Number STH034 3/12
VERSION 2 ICE MACHINES R404A OR R290
REFRIGERANT
The ice machine must be cleaned and sanitized a
minimum of once every six months. More frequent
cleaning may be required in some existing water
conditions. Always wear liquid-proof gloves and safety
glasses to prevent the cleaning and sanitizing
solutions from coming into contact with skin or eyes.
Use Manitowoc Ice Machine Cleaner part number
000000084.
Use Manitowoc Ice Machine Sanitizer part number
94-0565-3.
1. Turn off the ice making water supply and
disconnect power.
2. Remove the following parts:
Top by removing four thumbscrews.
Ice chute cover.
Ice dispense motor assembly by removing
four thumbscrews -Place motor assembly in a
location that it will not fall.
Ice chute by removing two thumbscrews.
There is a gasket between the ice chute and
ice extruding head that also needs to be
removed.
Remove ice bin cover and place cover in a
location that it will not fall
Remove all ice manually. Be cautious of the
washer in between the ice agitator and the
bottom of the ice bin.
3. Remove the following parts for cleaning and
sanitizing:
Ice agitator
Dispense wheel assembly
Small washer - It will be stuck to the bushing
or inside the agitator shaft.