Part Number STH034 3/12 71
26. Fill the freeze barrel with sanitizing solution where
the ice normally exits.
27. Allow the ice Machine to sit for about 10 minutes.
28. Replace ice chute, gasket and (2) black
thumbscrews.
29. Lay the unit top over the bin overflow switch. The
bin overflow switch must be depressed for the ice
machine to work properly.
30. Turn ON the ice Machine power switch.
31. Move the rocker switch to the “ICE” position.
32. Run the ice Machine for 20 minutes.
33. Turn OFF the ice Machine power switch.
34. Remove ice chute in order to replace parts.
NOTE: Discard the ice. Do not use ice made from the
sanitizing solution. Be careful not to leave any ice or
solution in the storage bin.
35. Rinse bin with water.
36. Replace all cleaned parts in their correct
positions:
• small washer
• assembled dispense wheel/plates
• auger
• bin cover
• motor
• gasket
• ice chute
• ice chute cover.
37. Replace the unit top cover with four thumbscrews.
38. Cleanup any spills on or around the unit.
39. Turn ON the ice Machine power switch.