Part Number STH034 3/12 27
Location
The location selected must meet the following criteria:
• The air temperature must be at least 40°F (4°C),
but must not exceed 90°F (32°C), climate class 4.
• The location must not be near heat-generating
equipment or in direct sunlight and must be
protected from weather.
• Water temperature min/max = 40°F/110°F
(4°C/43°C).
• Water supply pressure min/max = 30 psi/90 psi
(1.4 BAR/6.2 BAR).
• Always use the water supply line supplied when
installing this appliance. Never reuse an old supply
line.
• Main supply CO
2
pressure to Blend-In-Cup
Beverage System regulator min/max =
50 psi/80 psi (3.5 BAR/6.2 BAR).
• Minimum clearances must be maintained from all
walls and combustible materials.
• Keep equipment area clear of combustible
material.
Carbon Dioxide (CO
2
) displaces oxygen.
Exposure to a high concentration of CO
2
gas
causes tremors, which are followed rapidly by
loss of consciousness and suffocation. If a CO
2
gas leak is suspected, particularly in a small area,
immediately ventilate the area before repairing
the leak. CO
2
lines and pumps must not be
installed in an enclosed space. An enclosed
space can be a cooler or small room or closet.
This may include convenience stores with glass
door self serve coolers. If you suspect CO
2
may
build up in an area, venting of the B-I-B pumps
and / or CO
2
monitors must be utilized.