Part Number STH034 3/12 135
SYRUP SOLENOID VALVE
Function
Controls supply of CO
2
to product pump.
Specifications
24 VDC
Check Procedure
1. Verify pressure regulator setting is correct.
2. Verify pressure is present at valve inlet.
3. Check for 24 VDC at coil.
• 24 volts is not present - Refer to “Home Position
Switch” on page 139.
• 24 volts present - Continue
4. Relieve CO
2
pressure, then disconnect outlet line.
5. Restore CO
2
and test cycle valve:
• Valve opens - Check for pinched lines and
obstructions.
• Valve does not open - Replace valve