DRAIN CONNECTIONS
Follow these guidelines when installing drain lines.
Connect supplied 1" ID hose to hose-barb
connection on machine.
Drain lines must have a 1.5 inch drop per 5 feet of
run (2.5 cm per meter), and must not create traps.
The floor drain must be large enough to
accommodate drainage from all drains.
CO
2
Requirements
1. Connection Assembly — Use supplied 3/8"
panel-mounted hose barb and 6' (1.8 m) of
beverage tubing to connect coupling insert on
back of unit into CO
2
supply.
2. Supply pressure — 50 PSI (min.) and 80 PSI
(max.).
3. Product pressure — min. 35 PSI. Lowers the
CO
2
gas pressure before the CO
2
gas flows to the
product pump. CO
2
pressure activates the
product pump.
4. Beverage pump — Draws product out of the
product package. Product flows through the lines
to the dispenser for blending and dispensing.
There is a beverage pump for each product.
5. Product cassette — Contains a foil bag filled
with product.