© Munters AB, 2020 112
2. Under Minimum / Maximum Ventilation, enable
o
Dynamic Minimum Ventilation or
o
Dynamic Maximum Ventilation or
o
Both. In this example both are enabled.
3. Go to Climate > Min/Max Ventilation > Settings.
4. Define:
o
Dynamic Minimum Cold/Warm Outside Temperature: Define the cold temperature at
which dynamic ventilation begins operating.
o
Dynamic Maximum Cold/Warm Outside Temperature: Define the warm temperature at
which dynamic ventilation begins operating.
5. Go to Climate > Min/Max Ventilation.
6. Define:
o
Cold Min.: When the outside temperature reaches the Dynamic Minimum Cold Outside
Temperature, Minimum Ventilation is reduced by this amount.
o
Warm Min: When the outside temperature reaches the Dynamic Minimum Warm
Outside Temperature, Minimum Ventilation is increased by this amount.