12.2 Basic Ventilation
Basic Level Ventilation defines the amount of air to be supplied at each level of minimum ventilation level.
As the temperature increases, minimum ventilation increases the amount of air supplied in order to
maintain the temperature as close to the target temperature as possible
NOTE
Fans controlled by relays are on/off. When they are on, they run at maximum speed. Variable
fans’ speed can be controlled, according to needs.
•
Defining Basic Ventilation
•
Fan Options
•
Inlet and Curtain Ventilation
12.2.1 D
EFINING
B
ASIC
V
ENTILATION
In this configuration, TRIO raises the minimum ventilation from 10% at Level One to 100% at Level 10.
In Mapping and Defining the Input Output Devices, page 50 map relays and analog
output ports to fans, inlets, and stir fans as required. Only mapped devices show up in the
following screens.
1. Go to Climate > Ventilation.
NOTE
At this point, fans do not appear.
2. Click .
3. Click a relay controlled fan that you want to activate. 1) A box appears around the fan. 2) A fan
appears in the upper right.