© Munters AB, 2020 99
NOTE
For information on Brooding, refer to Brood Area, page 142.
8.2.2 D
EFINING
H
OUSE
M
ODES
“Flock Settings” Settings page defines basic parameters for houses when these room are NOT in Growth
mode. All other modes have the same parameters.
1. Click .
2. Click the required tab and define:
o
Ventilation Output: Define the ventilation output by percentage. (Empty and Pre-Heating).
o
Heat Output: Define the heat output.
o
Ventilation Level: Define the ventilation level (Catching mode only)
0 – 10 Basic
11 – 20 Extra
T1 – T3 Tunnel
o
Lights/Lights Intensity: Enable lighting and set the intensity (Catching mode only)
o
Alarm: Enable or disable temperature alarms.
o
Temp Low/High Alarm: Set the temperature below/above which the controller activates
a temperature alarm.
o
Timer: Enable or disable. Define which timers operate in this mode. Refer to Defining the
Timer, page 72 and Timers, page 162 for details on mapping and defining the Timers.