6. In System > Control Strategy > Ventilation , enable Extra Ventilation and/or Tunnel (refer to
Defining Extra Ventilation, page 128).
7. Go to Climate > Min. Max. Ventilation.
8. Place the cursor in Min Level or Max Level. The Basic/Extra/Tunnel icons appear.
9. Click the required ventilation icon.
10. Define the ventilation as required.
Options:
o
Defining Dynamic Ventilation
o
Ventilation by Weight
o
Adding a Curve
11.2.1 D
EFINING
D
YNAMIC
V
ENTILATION
Dynamic Ventilation means that at extreme temperatures (which the user defines), ventilation can be
increased or decreased.
1. Go to System > Control Strategy > Ventilation .