7.7 Inlets, Tunnel Doors, Outlets
Defining the Inlets/Tunnel Doors
Defining the Outlet
7.7.1 D
EFINING THE
I
NLETS
/T
UNNEL
D
OORS
Define up to four relays or analog output ports as inlets or tunnel doors (each device
requires two relays or one analogue port) (refer to Mapping Devices, page 50).
Define:
o
Normal State
o
Position: Define how the inlet opening is controlled:
By time
Potentiometer
o
Auto Calib.: Enable automatic calibration..
o
Power up calibration: Enable this parameter to calibrate inlets each time that TRIO is
turned on.
o
Open/Close Time: Enter the amount of time required to fully open or fully close the inlet.
These parameters are only enabled when Position/By Time is selected.