© Munters AB, 2020 114
4. Click .
5. Define:
o
Min Air Weight: The amount of air per bird’s weight to supplied.
o
Max: The maximum ventilation level by growth day.
NOTE
If you enabled Dynamic Ventilation, click Settings and define the parameters. Refer to Defining
Dynamic Ventilation, page 111.
11.2.3 A
DDING A
C
URVE
The following section shows have to configure your fans to increase in a curve between the days defined
in the Min Max Ventilation Screen.
1. Go to System > Control Strategy > Ventilation .
2. Enable Curve Status. Ventilation now increases in a curve.