7.5.2 D
EFINING THE
V
ARIABLE
H
EATERS
Define:
o
Min./Max Voltage: Define the voltage in the analogue output port that corresponds to
the 0% and 100% output, respectively.
o
Zone Heater:
Disable (default): Central Heaters, the heater output is related to the target
temperature, these heaters operate according to the average temperature (no
temperature sensors can be assign to it).
Enable: Zone Heater, the heater output has its own target set-point and its own
sensors assign to it. Zone heater enables the assignment of temperature sensor/s in
temperature definition.
o
KWh: This field displays the amount of kilowatts used. Read-only.