5. Define:
o
Enable Mode: Enable/disable the channel.
o
Storage Capacity: Define the quantity of feed that each silo can contain.
o
Calibrate: Refer to the next section.
7.14.2 C
ONFIGURING THE
S
ILO
S
CALE
The following procedure details how to “zero out” the TRIO silo scales. Zeroing out is way to ensure that
the unit’s A2D number is accurate (shown in the Silo Icon; 430 in the picture below). To summarize the
procedure:
The user enters the correct amount of feed in the silo while calibrating the silo scale. In the Silo
management screen, the user enters “0” (zero). TRIO/Echo 2 then defines the current A2D
signal to be the A2D signal for an empty bin.