12 Levels of Ventilation
•
Configuring the Basic Ventilation Settings
•
Basic Ventilation
•
Extra Ventilation
•
Tunnel Ventilation
•
Calibrating the Inlet/Tunnel Door
•
Stir Fan
12.1 Configuring the Basic Ventilation Settings
Map at least one ventilation device before beginning.
1. Go to Climate > Ventilation and click .
2. Define:
o
Efficiency Maximum: Refer to Fans (Efficiency Fan)
o
Ventilation Tuning: This parameter determines how aggressively the TRIO responds to
differences between the measured temperature and the target temperature.
CAUTION
Munters recommends leaving this paramter at Normal.
o
Increase/Decrease: TRIO continually reevaluates the difference between target and
measured temperatures. This parameter determines the reevaluation time frequency.
Leave at default.
CAUTION
Munters recommends leaving this function at the default.
o
Min Cycle Off Time (sec.): When using cycle time, TRIO automatically adjusts the ON
time set in the main screen. This parameter defines the minimum cycle off time. Range: 0
– 600 seconds.