Proximity to Edge: Inlets will open or close based on this proximity to the edge. For
example, when set to 10%, the curtain closes when the opening is less than 10% and
opens completely when the opening is greater than 90%.
o
Close Below This Temp. (out): Inlets close when the outside temperature reaches this
point.
12.6 Stir Fan
Stir fans mix the air within the rooms. To define the stir fan functionality:
1. Define a relay or analog port as a stir fan (refer to Mapping Devices, page 50).
2. Define the stir fan parameters (refer to Defining the Stir Fan, page 59).
3. Option: Define the stir fan cycle time (refer to Minimum Ventilation Cycle, page 118)
4. If the ventilation fans are running in a cycle, go to Climate > Ventilations > Settings.
5. Define when the stir fan operates, during the cycle On or Off time.