IOM-EZVAVINST
Date: 10-2016 Supersedes: 7-2016
Nailor reserves the right to change any information concerning product or specification without notice or obligation.
Page 26 of 48
Installation and Operation Manual
EZvav Digital Controls
Theairowbalancingprocedure(connue)
PROCEDURE STEPS STEDISPLAY
4 Measure and enter the actual
minimum primary airow.
The display begins ashing PMIN and also displays
the actual airow at the boom.
Note: The airow will aempt to stabilize on the
lowest value for either the cooling or heang minimum
airow even if only one mode is operaonal.
Note: The airow displayed by the STE-8000 in this
step is the actual, uncorrected airow.
1. Wait for the minimum airow value to stabilize.
2. With a ow hood, measure the actual airow.
3. Press the
buon to advance to the entry display.
PMIN stops ashing.
4. Press the
or buons to enter the measured
airow.
5. Press the
buon to save the measured airow.
The display advances to PRI.


5 Advance or exit.
1. Press the
or buons to select one of the
following:
SEC to balance the secondary VAV for dual duct
systems. Choosing SEC advances to the SMAX
display. This is available only on dual duct models.
BACK to choose another commissioning funcon
EXIT to return to the temperature display.
2. Press the
buon to select the next funcon.
6 Measure and enter the actual
maximum secondary airow.
The display begins ashing SMAX and also displays
the actual airow at the boom.
Note: The airow displayed by the STE-8000 in this
step is the actual, uncorrected airow.
1. Wait for the maximum airow value to stabilize.
2. With a ow hood, measure the actual airow.
3. Press the
buon to advance to the entry display.
SMAX stops ashing.
4. Press the
or buons to enter the measured
airow.
5. Press the
buon to save the measured airow.
The display advances to SMIN.


7 Measure and enter the actual
minimum secondary airow.
The display begins ashing SMIN and also displays
the actual airow at the boom.
Note: The airow displayed by the STE-8000 in this
step is the actual, uncorrected airow.
1. Wait for the minimum airow value to stabilize.
2. With a ow hood, measure the actual airow.
3. Press the
buon to advance to the entry display.
SMIN stops ashing.
4. Press the
or buons to enter the measured
airow.
5. Press the
buon to save the measured airow.
The display advances to SEC.



