nish framing
10.4 alcove enclosure
APPLIANCE
RECESS OR
ALCOVE
AREA
The recesses or alcoves can be made as deep as desired provided the minimum clearances to combustibles are
maintained.
The minimum enclosure volume must be increased by no less than the volume of the recess. This adjustment can
be made by increasing any or all of the height, width and depth of the enclosure.
ENCLOSURE
AREA
note:
Recesses or alcoves above the appliance must be made with non-combustible material and regular minimum
clearances, as defined for combustible materials, must still be applied.