135
Solution: Check that the MAXserver is in the RUN state and that the
Ethernet transceiver cable or 10BASE-T network cable is properly installed.
Load Server Errors
A message similar to the following one is displayed if the MAXserver has
received a load offer from a load server:
EVALUATING SERVICE OFFERS
If you typed a <CTRL><T> after "autobauding" your terminal, messages
similar to the following display when the unit has stopped accepting load
offers:
Received load service offers:
Host Address protocol merit filename
xx-xx-xx-xx-xx-xx 0809 9C000037 XPCSRV20
Up to ten load server addresses are displayed (typically, just one). The
MAXserver unit selects the load server with the highest merit value.
When the MAXserver chooses a load server, a message similar to this one
appears:
Access server, Type 86, Rev x.xx.x
Ethernet address 08-00-87-xx-xx-xx, port x
Currently using initialization record 1
Loading file xpcsrv20
from server xxx.xxx.xxx.xxx, message 1487
Memory Card; Not Installed
Error: Message count stays at zero while you type <RETURN>
continuously.
Problem: The load server was configured to load the MAXserver unit, but
encountered a problem with the load file or directory.
Possible Solutions: Check the filename and directory at the load server.
Additionally, in some newer VAX/VMSinstallations, the logical name