CABLE TERMINATION 6-3
Installation NWD-107460-02E
6.1 5D Coaxial Cable
Procedure 6-1 TNC-P Connector used for IDU IF IN/OUT
(L-angle:TNC150(R0))
1 Insertion of parts, remove of jacket of cable.
(1) The clamp nut is inserted as shown.
(2) Remove 8 mm of jacket only.
Note Do not damage the braided wire.
Tools
knife, cutter, nipper, tweezers, file, measure,
clearance gauge, etc.
spanner, torque spanner 14 mm
Outlines of parts
[Applicable cable: 5D-FB-E]
Cable jacket
Aluminum tape
Braided wire
Insulator
Center conductor
Connector body
Clamp Clamp nut
Cable
Clamp nut
(8 mm)
*Cut the jacket edge squarely.