1. Turn the power off, insert the Customer Data CF card into the CF Slot on PZ-VM21.
CPU card
CF Slot (CN2)
CF card
PZ-VM21 PCB
Figure 3-13 Inserting the CF card
2. Turn the power on, enter the Program Mode then PRG90-04.
Program Mode
90-04-01
Data Load
Figure 3-14 PRG90-04 Display
3. Dial 1 and press Hold key.
4. When the data backup to the CF card is completed, the display changes to the next PRG.
90-04-01
Loading Data
90-05- M
,
tenanc
Slot Control
Figure 3-15 Next PRG Display
5. Remove the CF card and exit from the Program Mode.