SECTION 2 SYSTEM SPECIFICATIONS
2.1 General Precautions
Never attempt to insert wires, pins, etc. into the vents or other holes of the equipment.
Do not use benzene, thinner, or the like, or any abrasive powder to clean the equipment. Wipe it
with a soft cloth.
2.2 Environmental Requirements
Meeting established environmental standards maximizes the life of the system. Be sure that the site is
not:
In direct sunlight or in hot, cold or humid places.
In dusty areas or in areas where sulfuric gases are produced.
In places where shocks or vibrations are frequent or strong.
In places where water or other fluids comes in contact with the equipment.
In areas near high-frequency machines or electric welders.
Near computers, telexes, microwaves, air conditioners, etc.
Near radio antennas (including shortwave)
2.3 Operating Conditions
Table 5-2 Operating Conditions
Unit Operating Conditions
KSU, PCBs and Multiline Telephones Temperature: 0 to +40 degree C (32 to 104 degree F)
Humidity: 10 to 90% (non-condensing)
Doorphone Box Temperature: -20 to +60 degree C (-4 to 140 degree F)
Humidity: 20 to 80% (non-condensing)
2.4 Site Requirements
A KSU can only be wall-mounted, it can only be floor-mounted if the optional External Backup Battery
Box is installed.
2.5 AC Power Requirement
A dedicated 100V-120V/220V/230V/240V 50/60Hz circuit located within 2 meters of the KSU is
required. A separate dedicated AC outlet is necessary for each KSU.
Double Pole/Neutral Fusing
(Power supply fuses are located at both the L and N side.)
Table 5-3 Power Requirement
110 VAC 220 VAC 230 VAC 240 VAC
Power Require-
ments
110 VAC@15 A 220 VAC@15 A 230 VAC@15 A 240 VAC@15 A
Power Con-
sumption
Main KSU = 144 VA
4 KSU Total = 576 VA
Main KSU = 172 VA
4 KSU Total = 688 VA
Main KSU = 175 VA
4 KSU Total = 700 VA
Main KSU = 175 VA
4 KSU Total = 700 VA
Input Voltage
(Rated Voltage)
90 VAC to 264 VAC (100VAC/120VAC/220VAC/230VAC/240VAC)
ISSUE 3.0 SL1000
Hardware Manual 5-3