NEC SL1000 - Figure 2-23 PF;KT Switch of 408 M-A1

NEC SL1000
150 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Trunk Port No. 1 Extension Port No. 8
The connected extension must be SLT (Single Line Telephone).
Hardware switch (J6) must be set from "KT" to "PF" side (default: KT) when use the Power failure
transfer circuit.
Refer to Power Failure Transfer on page 2-58 for Power Failure Transfer of 408E-A1.
1.6.5.2 Power Failure Setting
1. Use Needle-nose pliers to change the switch position of "J6" from "KT" to "PF" as below.
(Default: KT)
J6
PF
Port
KTPF KTPF
Multiline
Telephone
PF
Port
Multiline
Telephone
Figure 2-23 PF/KT Switch of 408M-A1
2. Connect a SLT to the extension port No. 8.
SL1000 ISSUE 3.0
2-18 Installation