Items 1 KSU
(1632)
2 KSU
(3264)
3 KSU
(4896)
4 KSU
(64128)
Note
Station Port 4W Key Set 24 48 72 96 Max. 24/KSU
SLT (–28V) 32 64 96 128 1KSU: 408M+408Ex3
2KSU: 408Mx2+408Ex6
3KSU: 408Mx3+408Ex9
4KSU: 408Mx4+408Ex12
BRI (S-Point) 12 24 36 36 1KSU: 2BRIx3 on 008E/000E
2KSU: 2BRIx6 on 008E/000E
3KSU: 2BRIx9 on 008E/000E
4KSU: 2BRIx12 on 008E/000E
4W DSS Console 3 6 9 12 Max. 3/KSU
Connect to HBI Port 8 at 408M/408E/008E
Doorphone 2 4 6 8 2DPH I/F on 408M (HBI port 6,7)
Needs Program setting.
Alternative use with SLT
SIP-MLT/ SIP Std.
terminal
16 When MEMDB is installed
VRS Channels 4 CFVRS-C1
Max. 16 When MEMDB is installed
VM/VRS Channels 2 VM ports/ 4 VRS ports (default)
(Total Max.8 w/o MEMDB or 16 w/
MEMDB)
CFVMS-C1
Port increased by license.
4 VM ports/ 4 VRS ports (default)
(Total Max.8 w/o MEMDB or 16 w/
MEMDB)
CFVML-C1
Port increased by license.
Virtual Extension 50
Relay 2 4 6 8 2 circuits on 408M
Power Failure Transfer 4 8 12 12 1PFT circuit on 408M and 408E (COI port
1 and HBI port 8)
Needs HW switch change. Alternative use
with SLT.
Ethernet Port 1 1 circuit on CPU
Built-In Answering Machine Chan-
nel
1 1 circuit on CPU
VoIP Channels 16 When MEMDB is installed
V34 Modem 1 1 circuit on PZ-VM21
Conference Circuits 32 (Max. 16 parties per Conference) Mounted on CPU
DSP Resource
*1
20 For 1632M KSU (DSP on CPU)
16 When PZ-VM21 is installed
- 32 64 96 For 1632ME EXP 32ch DSP on each EX-
IFE-C1
DSP Sender
*2
128
*1. Service Tone receiver, DTMF receiver, Caller ID sender / receiver, MF receiver, MFC receiver
*2. Service Tone sender, DTMF sender, MF sender, MFC sender
SL1000 ISSUE 3.0
5-2 Specifications