P57E
PROGRAM MODE LEVEL
Installer mode or NessComms.
FACTORY DEFAULT
All ON: All zones trigger Siren output.
NOTES
0E will turn all selections OFF
MEMORY E will turn all selections ON
SIREN OUTPUT ZONES
Selects the zones to trigger the Siren output.
PROGRAMMING SEQUENCE:
P57E [Zone No]E toggles the options ON and OFF
[Zone No] OFF: The zone will not trigger the Siren output
[Zone No] ON: The zone will trigger the Siren output
P58E
PROGRAM MODE LEVEL
Installer mode or NessComms.
FACTORY DEFAULT
All OFF: No zones trigger AUX1.
NOTES
0E will turn all selections OFF.
MEMORY E will turn all selections ON.
RELATED OPTIONS
P121E 5E-8E Day zone output mapping.
AUX1 OUTPUT ZONES
Selects the zones to trigger the AUX1 output on the main board. This option selects
which zones trigger AUX1. Use P121E to enable the ouput.
Once turned on by a zone alarm, the output will remain on until the panel is reset/
disarmed.
PROGRAMMING SEQUENCE:
P58E [Zone No]E toggles the options ON and OFF
[Zone No] OFF: The zone will not trigger the AUX1 output
[Zone No] ON: The zone will trigger the AUX1 output
P59E
PROGRAM MODE LEVEL
Installer mode or NessComms.
FACTORY DEFAULT
All OFF: No zones trigger AUX2.
NOTES
0E will turn all selections OFF.
MEMORY E will turn all selections ON.
AUX2 OUTPUT ZONES
Selects the zones to trigger the AUX2 output on the main board. This option selects
which zones trigger AUX2. Use P122E to enable the ouput.
Once turned on by a zone alarm, the output will remain on until the panel is reset/
disarmed.
PROGRAMMING SEQUENCE:
P59E [Zone No]E toggles the options ON and OFF
[Zone No] OFF: The zone will not trigger the AUX2 output
[Zone No] ON: The zone will trigger the AUX2 output
23
Ness D8x / D16x Control Panel – Installation Manual
PROGRAMMING