Option No. Description Default Note
P26E ENTRY DELAY TIME 1 20 seconds
P27E ENTRY DELAY TIME 2 6 x10 = 60seconds
P28E EXIT DELAY TIME 60 seconds
P29E SIREN RESET TIME 5 minutes
ENTRY DELAY TIME1
The Entry Delay Time 1 is the time given to disarm the panel after a Entry Delay 1 zone
is unsecured.
The Entry Delay Time1 setting is from 1 to 99 seconds in 1 second increments. Entry
Delay Time1 can be up to a maximum of 990 seconds by enabling options P120E 7E.
PROGRAMMING SEQUENCE:
P26E existing time is displayed one digit at a time
[ENTER NEW TIME] E new time is displayed one digit at a time
EXAMPLE: To program Entry Delay Time1 to be 30 seconds: P26E 30E
P26E
PROGRAM MODE LEVEL
User, Installer mode or NessComms.
FACTORY DEFAULT
20 (seconds)
NOTES
delay before Auto Re-Arming. See P68E
2E page 34.
RELATED OPTIONS
P120E 7E Entry Delay Extender
ENTRY DELAY TIME2
The Entry Delay Time2 is the time given to disarm the panel after an Entry Delay2 zone
is unsecured.
The Entry Delay Time2 setting is from 10 to 990 seconds (1 – 99).
Note: The Entry Delay Time2 is set in 10 second increments so that a value setting of 6
means a 60 seconds delay.
PROGRAMMING SEQUENCE:
P27E existing time is displayed one digit at a time
[ENTER NEW TIME] E new time is displayed one digit at a time
EXAMPLE: To program Entry Delay Time2 to be 600 seconds:
P27E 60E
P27E
PROGRAM MODE LEVEL
User, Installer mode or NessComms.
FACTORY DEFAULT
6 (= 60 seconds)
NOTES
Programmable from 10 – 990 seconds.
EXIT DELAY TIME
The Exit Delay Time is the time given to secure and depart the premises after the panel
is armed. All zones (except 24hr zones) are inactive during the Exit Delay time.
The Exit Delay Time setting is from 1 to 99 seconds in 1 second increments.
PROGRAMMING SEQUENCE:
P28E existing time is displayed one digit at a time
[ENTER NEW TIME] E new time is displayed one digit at a time
EXAMPLE: To program Exit Delay to be 85 seconds:
P28E 85E
P28E
PROGRAM MODE LEVEL
User, Installer mode or NessComms.
FACTORY DEFAULT
60 (seconds)
NOTES
Programmable from 1 – 99 seconds
RELATED OPTIONS
P62E 8E Exit Time x10
SIREN RESET TIME
The Siren Reset Time sets the duration of the Siren and Reset outputs.
The Siren Reset Time setting is from 1 to 99 minutes in 1 minute increments.
PROGRAMMING SEQUENCE:
P29E existing time is displayed one digit at a time
[ENTER NEW TIME] E new time is displayed one digit at a time
EXAMPLE: To program Siren Time to be 4 minutes:
P29E 4E
P29E
PROGRAM MODE LEVEL
Installer mode or NessComms.
FACTORY DEFAULT
5 (minutes)
NOTES
contrary to noise pollution regulations in
most areas.
16
Ness D8x / D16x Control Panel – Installation Manual
PROGRAMMING