TELEPHONE REMOTE CONTROL
The D8x/D16x will allow a user to call
in to the panel, using a standard DTMF
telephone, and remotely Arm or Disarm
all areas and also turn on or off Aux
outputs 1, 2, 3 or 4.
To maintain panel security, remote
operations can only be activated after
entering a valid user code.
To operate the panel by telephone, you
need a DTMF capable telephone, a
valid user code and you must know the
telephone number of the line to which
the panel is connected.
The panel must be enabled for Remote
Telephone Operation. See P90E
options.
NOTES

commands for periods longer than 10
seconds it will assume that the call is
finished and it will hang up.

the panel to dial out while attempting
remote control, the Panel will treat the
alarm as a priority, give a constant tone
as a warning and then hang up.

are finished press
to force the
panel to hang up.
SUMMARY OF TELEPHONE COMMANDS
Prepare to receive commands
Arm Areas
Disarm Areas
Turn ON or Pulse AUX1
Turn OFF AUX1
Turn ON or Pulse AUX2
Turn OFF AUX2
Turn ON or Pulse AUX3
Turn OFF AUX3
Turn ON or Pulse AUX4
Turn OFF AUX4
Finished – hang up
SEQUENCE OF OPERATION.
1. Phone the panel telephone number
and listen for the required number
of rings (the normal double ring is
counted as one ring) and then hang
up.
2. Wait 10 seconds and then call the
number again within 50 seconds.
3. The panel will answer the second
call immediately, sound a beep for
2 seconds then, after a pause, it
will sound a lower frequency tone.
The panel is now ready to receive
telephone commands.
4. Press the
button on the
telephone. This tells the panel that
telephone commands will follow.
The panel will respond with either
3 beeps if all OK (One long beep
means try again).
5. Now enter a valid User Code (that
is normally used for Arming or
Disarming the panel) followed by the
button.
The panel will respond with 3 beeps
if it recognises the code or 1 long
beep to signal the code was invalid
and to try again.
6. Enter the required command.
See: Summary Of Telephone
Commands.
7. Press
to finish. This tells the
panel to hang up.
AUDIBLE FEEDBACK
3 beeps


Disarming

been turned ON.
1 long beep



not enabled
1 short beep

been turned OFF.
RELATED OPTIONS
P141E 5E, Telephone remote control of AUX1
P142E 5E, Telephone remote control of AUX2
P143E 5E, Telephone remote control of AUX3
P144E 5E, Telephone remote control of AUX4
80
Ness D8x / D16x Control Panel – Installation Manual

Table of Contents

Other manuals for Ness D8X

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Ness D8X and is the answer not in the manual?

Ness D8X Specifications

General IconGeneral
BrandNess
ModelD8X
CategoryControl Panel
LanguageEnglish

Related product manuals