DISABLE DIALLER
This option disables the dialler even if telephone numbers and other dialler options are
programmed.
Up/download or remote telephone access remain enabled.
PROGRAMMING SEQUENCE:
P86E 1E turns the option ON
ON: Dialler disabled
P86E 1E
PROGRAM MODE LEVEL
Installer mode or NessComms.
FACTORY DEFAULT
Off: dialler enabled.
NOTES
This option is useful for temporary
disabling of the dialler without affecting
other dialler options.
CONTACT ID FORMAT
This option enables the reporting of alarms to a Central station via telephone numbers
PROGRAMMING SEQUENCE:
P86E 2E turns the option ON
ON: Contact ID format enabled
P86E 2E
PROGRAM MODE LEVEL
Installer mode or NessComms.
FACTORY DEFAULT
ON: Contact ID format enabled.
REPORT NAME SSSS Q XYZ GG CCC SUFFIX
Zone 1– Zone 16 Alarm ssss 18 q 130 aa 001–016 k
Duress ssss 18 1 121 01 030 k
Keyswitch Panic ssss 18 1 120 01 031 k
Keypad Panic ssss 18 1 120 01 032 k
Radio Key Panic ssss 18 1 120 01 1dd k
Medical Alarm ssss 18 1 100 01 033 k
Fire ssss 18 1 110 01 034 k
Exit Install mode ssss 18 1 306 01 035 k
External Tamper ssss 18 q 137 01 040 k
Internal Tamper ssss 18 q 137 01 041 k
Keypad Tamper ssss 18 q 137 01 042 k
Radio Sensor Supervision ssss 18 q 381 01 4zz k
Radio Sensor Tamper ssss 18 q 383 01 2zz k
Radio Sensor Low Battery ssss 18 q 384 01 3zz k
Mains Fail ssss 18 q 301 01 050 k
Panel Battery Fail ssss 18 q 309 01 051 k
Open (Disarm) ssss 18 1 402 aa 0dd k
Force Open (Cancel) ssss 18 1 406 aa 0dd k
Close (Arm) ssss 18 3 402 aa 0dd k
Closing Extended ssss 18 3 464 aa 0dd k
Test Report ssss 18 1 602 01 063 k
Zone 1-16 Manual Exclude ssss 18 q 573 aa 001-016 k
Zone 1-16 Auto Exclude ssss 18 q 380 aa 001-016 k
CONTACT ID REPORTS TABLE
The panel reports alarms to the Central
Station using Contact ID dialler format.
The message format is fixed as shown
in the Contact ID Codes Table.
The message takes the form of:
SSSS Account Number
Q Event qualifier
1=New Event or Open
3=Restore or Close
XYZ Alarm type
GG Group or Area designation
CCC Alarm number
dd=User ID (1 to 56)
zz = Zone ID (1 to 16)
aa = 01 Area 1
aa = 02 Area 2
aa = 01 Monitor area
aa = 00 24 Hr Area
K = Checksum
(0 to 0f hex)
SPECIAL ARMING/DISARMING REPORTS BY USER
Option No. Description Default
P86E
1E Disable Dialler
OFF
2E CONTACT ID FORMAT
ON
3E [not used]
OFF
4E Audible VOICE Format
OFF
5E [not used]
OFF
6E Contact ID + VOICE Format
OFF
REPORT NAME User ID
Arm/Disarm by Keyswitch 57
Shortcut Arm 58
Arm/Disarm by AutoTimer 1 91
Arm/Disarm by AutoTimer 2 92
Arm/Disarm by AutoTimer 3 93
REPORT NAME User ID
Arm/Disarm by AutoTimer 4 94
Arm/Disarm by AutoTimer 5 95
Arm/Disarm by AutoTimer 6 96
Arm/Disarm by AutoTimer 7 97
Arm/Disarm by AutoTimer 8 98