TAMPER ALARM / OUTPUT MAPPING
This option selects which outputs will trigger when a Tamper Alarm occurs.
PROGRAMMING SEQUENCE:
P61E 1E–4E toggles the options ON and OFF
1E ON: Tamper Alarm to Reset output
2E ON: Tamper Alarm to Strobe output
3E ON: Tamper Alarm to Keypad Sonalert output
4E ON: Tamper Alarm to Siren output
P61E 1E–4E
PROGRAM MODE LEVEL
Installer mode or NessComms.
FACTORY DEFAULT
1E–4E, ON: Tamper alarm triggers all
outputs.
NOTES
TAMP input or by removing the the J1
PROG/TAMP link on the main board.
KEYPAD PANIC ALARM / OUTPUT MAPPING
This option selects which outputs will trigger when a Keypad Panic alarm occurs.
PROGRAMMING SEQUENCE:
P61E 5E–8E toggles the options ON and OFF
5E ON: Keypad Panic Alarm to Reset output
6E ON: Keypad Panic Alarm to Strobe output
7E ON: Keypad Panic Alarm to Keypad Sonalert output
8E ON: Keypad Panic Alarm to Siren output
P61E 5E–8E
PROGRAM MODE LEVEL
Installer mode or NessComms.
FACTORY DEFAULT
5E–8E, ON: Panic alarm triggers all
outputs.
NOTES
by the PANIC keys on the keypad (* E
or ** together, depending on Option
P64E6E).
Option No. Description Default
P61E
1E Tamper to RESET output
ON
2E Tamper to STROBE output
ON
3E Tamper to Keypad Sonalert
ON
4E Tamper to SIREN output
ON
5E Keypad Panic to RESET output
ON
6E Keypad Panic to STROBE output
ON
7E Keypad Panic to Sonalert
ON
8E Keypad Panic to SIREN output
ON
26
Ness D8x / D16x Control Panel – Installation Manual
PROGRAMMING