SUPERVISED ZONES
Any zone 1-8 or 1-16 can be a Supervised Zone.
Supervision for HARDWIRED ZONES
In operation, a Supervised Zone is subject to the Supervision Time (P67E). If the zone/s
has not sealed or unsealed during the Supervision Time, then the programmed alerts
will turn on (as programmed by P66E 1E-4E, P92E 4E or P75E 12E). Zone Supervision

zone has had no activity during a set period of time. (For example, to monitor an aged
person's home).

Supervision Time will be treated as a Supervision alarm.
Zone
Supervision acts on radio zones.




valid code + E will reset Supervision alarms.
Supervision for RADIO ZONES
The purpose of Radio Supervision is to verify the correct operation of Ness Radio PIRs.
The Supervision signal from the Radio PIR tells the panel that the device has not been
removed from radio range and is in working order.
A non-SUPERVISION enabled Radio PIR will transmit signals to the panel only when it
has detected an event. Obviously, there is no guaranteed signal period.
In either case, when the allowed time limit is exceeded then a WARNING is first
given (if programmed by P66E 3E), and then after 1 minute, the programmed RADIO
SUPERVISION ALERTS are generated by the panel.
P66E 5E must be off for supervision to work on radio zones.
PROGRAMMING SEQUENCE:
P65E [Zone No]E toggles the options ON and OFF
[Zone No]E OFF: The zone is not a Supervised Zone
[Zone No]E ON: The zone is a Supervised Zone
P65E
PROGRAM MODE LEVEL
Installer mode or NessComms.
FACTORY DEFAULT
all OFF: No Supervision zones.
RELATED OPTIONS
P66E 1E–4E Supervision Alerts.
P66E 5E Wired Zone Supervision.
P67E Zone Supervision Time.
P92E 4E (D8) Report Supervision.
P75E 12E (D16) Report Supervision.
NOTES
0E will turn all selections OFF.
MEMORY E will turn all selections ON.
If Radio Supervision is enabled, P66E
5E off, then the supervision feature
cannot be used as an inactivity monitor.
ZONES 1–8 (D8 & D16) ZONES 916 (D16)
Option No. Description
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
P65E SUPERVISED ZONES
31
Ness D8x / D16x Control Panel – Installation Manual
PROGRAMMING

Table of Contents

Other manuals for Ness D8X

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Ness D8X and is the answer not in the manual?

Ness D8X Specifications

General IconGeneral
BrandNess
ModelD8X
CategoryControl Panel
LanguageEnglish

Related product manuals