50Hz MAINS FREQUENCY
Selects either 50Hz or 60Hz mains power frequency operation. Leave the factory
default for use in Australia and New Zealand. Users in North America should select
60Hz mains frequency.
Required for the accurate timing of dialler test reports (if programmed). It has no effect
on local or other dialler operations.
PROGRAMMING SEQUENCE:
P64E 5E toggles the option ON and OFF
OFF: 60Hz mains frequency
ON: 50Hz mains frequency
P64E 5E
PROGRAM MODE LEVEL
Installer mode or NessComms.
FACTORY DEFAULT
ON: 50Hz mains frequency.
NOTES
KEYPAD FIRE ALARM (STD LCD KEYPAD)
This option enables the Keypad Fire Alarm. Pressing and then triggers the

If P75E 4E is enabled, the fire alarm is reported by dialler to the central station.
PROGRAMMING SEQUENCE:
P64E 7E toggles the option ON and OFF
OFF: No Keypad Fire Alarm
ON: Keypad Fire Alarm enabled
P64E 7E
PROGRAM MODE LEVEL
Installer mode or NessComms.
FACTORY DEFAULT
OFF: No Keypad Fire Alarm.
RELATED OPTIONS
P68E 6E Fire Siren sound.
P75E 4E Report Fire Alarms.
NOTES
Applies only to the standard Ness LCD
keypad, not the Ness KPX keypad.
See options P126E for KPX double key
options.
KEYPAD MEDICAL ALARM (STD LCD KEYPAD)
This option enables the Keypad Medical Alarm. Pressing and then activates
the dialler and reports a Medical Alarm.
If P75E 2E must be enabled for the Medical alarm to be reported.
PROGRAMMING SEQUENCE:
P64E 8E toggles the option ON and OFF
OFF: No Keypad Medical Alarm
ON: Keypad Medical Alarm enabled
P64E 8E
PROGRAM MODE LEVEL
Installer mode or NessComms.
FACTORY DEFAULT
OFF: No Keypad Medical Alarm.
RELATED OPTIONS
P75E 2E Report Medical Alarms.
NOTES
Applies only to the standard Ness LCD
keypad, not the Ness KPX keypad.
See options P126E for KPX double key
options.
STROBE FLASH ON HOME ARMING BY RADIO
This option enables a brief strobe flash when arming Home Mode by radio key or radio
keypad. This applies to Home Mode arming only, disarming Home Mode by radio key
never flashes the strobe.
PROGRAMMING SEQUENCE:
P64E 6E toggles the option ON and OFF
OFF: No strobe flash
ON: Strobe flash enabled
P64E 6E
PROGRAM MODE LEVEL
Installer, Remote by PC.
FACTORY DEFAULT
OFF: No strobe.
NOTES
This is not related to strobe flash on
arming and diarming area 1 or 2 by
radio key, which always flashes the
strobe on arm and disarm.
RELATED OPTIONS
P69E 5E Home Mode arming by radio
key.
P120E 2E Siren Chirp on Home Arming
by Radio
30
Ness D8x / D16x Control Panel – Installation Manual
PROGRAMMING

Table of Contents

Other manuals for Ness D8X

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Ness D8X and is the answer not in the manual?

Ness D8X Specifications

General IconGeneral
BrandNess
ModelD8X
CategoryControl Panel
LanguageEnglish

Related product manuals