OPTION DESCRIPTION
DEFAULT
PAGE
P70E TELEPHONE NO.1 Primary
NONE
38
P71E Telephone No.2 Secondary
NONE
P72E ACCOUNT NO. 1
0000
39
P73E Account No. 2
0000
P74E
REPORT ZONE ALARMS
All zones
40
P75E
1E Report DURESS alarms
OFF
41
2E Report MEDICAL alarms
OFF
3E
ON
4E Report FIRE alarms
OFF
5E Report PANEL TAMPER alarms
ON
6E Report EXTERNAL TAMPER alarms
ON
7E Report KEYPAD TAMPER alarms
ON
8E Report EXIT FROM INSTALLER mode
OFF
D8, P92E 1E
Report RADIO TAMPER
ON
D16, P75E 9E
D8, P92E 2E
Report RADIO PANIC by User ID
ON
D16, P75E 10E
D8, P92E 3E
Report RADIO Low Battery by device
OFF
D16, P75E 11E
D8, P92E 4E
Report ZONE SUPERVISION FAIL
OFF
D16, P75E 12E
D8, P92E 5E
Report PANEL LOW BATTERY
ON
D16, P75E 13E
D8, P92E 6E
Report MAINS FAIL
ON
D16, P75E 14E
P76E
Report Zone Restorals
All on
40
P77E
Report Misc. Restorals
All on
41
P78E
Report Multiple Zone alarms
NONE
40
P79E
Account No.2 zones
NONE
40
P80E
Tel No. 3 for Test Calls
NONE
39
P81E
Tel No.4 Callback
NONE
P82E
1E
Send RESTORAL report immediately
OFF
41
2E
Send RESTORAL after siren time
OFF
3E
OFF
4E
Send RESTORAL after Disarm always
ON
P83E
TEST CALL Interval
84 (168hrs)
42
P84E
Time before NEXT TEST CALL
6 (12hrs)
P85E
1E
OFF
42
2E Pulse Dialling (Decadic) always
OFF
3E DTMF Dialling always
ON
P86E
1E Disable Dialler
OFF
43, 44
2E CONTACT ID FORMAT
ON
3E [not used]
OFF
4E Audible VOICE Format
OFF
5E [not used]
OFF
6E Contact ID + VOICE Format
OFF
P87E
1E Split dial Primary/Secondary numbers
OFF
45
2E Check for Dial Tone
ON
3E [not used]
OFF
4E 4 Dialling attempts
ON
P88E
1E Send AREA 1 OPEN/CLOSE REPORTS
OFF
46, 47
2E Send AREA 2 Open/Close reports
OFF
3E Siren Chirp on Kiss-off
OFF
4E Flash Strobe on Kiss-off
OFF
5E Forced Opening report
ON
6E Delayed Closing Reports
OFF
7E Manual Exclude Reports
ON
8E Auto Exclude Reports
ON
D8x/D16x V6 PROGRAMMING OPTIONS SUMMARY
Page 3 of 5
OPTION DESCRIPTION
DEFAULT
PAGE
P89E
1E ENABLE TEST CALLS
ON
48, 49
2E Mains Report Delay (1 hour)
ON
3E Listen-In to Dialler
OFF
4E Swinger shutdown
ON
5E Line Fault Monitor
OFF
7E Use Internal Timing
OFF
P90E
1E Enable Remote Access
OFF
50, 51
2E Enable First Call Mode
OFF
3E Enable Remote Arming
OFF
4E Enable Remote Disarming
OFF
5E Enable Remote AUX control
OFF
6E Enable Remote Status reporting
OFF
7E Enable Remote Event Report
OFF
8E Enable Callback Mode
OFF
P91E Required rings to answer
1
52
P92E Report Misc. Alarms 9-14 (D8 only)
1,2,5,6 on
41
P93E Report Misc. Restorals 9-14 (D8 only)
All on
P94E
none
52
P95E CLEAR RADIO DEVICES
53
P96E CLEAR MEMORY
P97E CLEAR PANEL OPTIONS
(restore Factory Defaults)
P98E
CLEAR User codes, Radio Keys, Access Cards
P99E Program the INSTALLER CODE
000000
53
P101E-P116E
PROGRAM RADIO DEVICES 1–8 or 1–16 none
71
P117E
1E Enable Output Expander
OFF
54, 55
2E Alternate Expander Format
OFF
3E Day Zone Follower
OFF
4E Output Exclude
OFF
P118E Output Expander zones
none
P119E Output Expander alarm zones
none
P120E
1E Latched keyswitch input
OFF
56
2E
Home arm chirps by radio key
OFF
3E
Radio Key AUX arms Home mode OFF
4E Keyswitch DISARM ONLY
OFF
5E Keyswitch ARM ONLY
OFF
6E Smart Beeps
OFF
7E Entry Delay Extender
OFF
8E Area2 Disarm by Keyswitch Allowed
OFF
P121E
1E
Zone alarms to AUX1 (P58E selects zones)
ON
58
2E Zone Supervision alarms to AUX1
OFF
3E Radio key Panic TOGGLE
OFF
4E Radio key Panic PULSE
OFF
7E Door Open Too Long (DOTL) alarm to AUX1
OFF
8E Reader [x] output to AUX1
OFF
P122E
1E
Zone alarms to AUX2 (P59E selects zones)
ON
60
2E Zone Supervision alarms to AUX2
OFF
3E Radio key Aux Button TOGGLE
OFF
4E Radio key Aux Button PULSE
OFF
5E Telephone Line fault to AUX2
OFF
7E Door Open Too Long (DOTL) alarm to AUX2
OFF
8E Reader [x] output to AUX2
OFF
P123E
3E
Enable AUX3 for AutoTime OFF
62
8E Reader [x] output to AUX3
OFF
83
Ness D8x / D16x Control Panel – Installation Manual