EasyManuals Logo

NETGEAR FS728TPv2 User Manual

NETGEAR FS728TPv2
261 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #150 background imageLoading...
Page #150 background image
150 | Chapter 5: Managing Device Security
FS728TP Smart Switch Software Administration Manual
To display the TACACS+ Server Configuration page, click Security Management Security,
and then click the TACACS+ Server Configuration link.
To configure TACACS+ server settings:
1. To add a new TACACS+ server, select Add from the TACACS+ Server field, enter the
IP address of the server to add, and click Apply.
Note: The Add option is available if fewer than five TACACS+ servers are
configured on the system, and the Server Address field is only
available when Add is selected in the TACACS+ Server IP Address
field.
After you add one or more TACACS+ servers, additional fields appear on the TACACS+
Server Configuration page.
2. In the Priority field, specify the order in which the TACACS+ servers are used. A value of 0
is the highest priority.
3. In the Port field, specify the authentication port number through which the TACACS+
session occurs. The default is port 49, and the range is 0–65535.
4. In the Key String field, specify the authentication and encryption key for TACACS+
communications between the FS728TP and the TACACS+ server. This key must match the
encryption used on the TACACS+ server. The valid range is 0–128 characters.

Table of Contents

Other manuals for NETGEAR FS728TPv2

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the NETGEAR FS728TPv2 and is the answer not in the manual?

NETGEAR FS728TPv2 Specifications

General IconGeneral
BrandNETGEAR
ModelFS728TPv2
CategorySwitch
LanguageEnglish

Related product manuals