EasyManuals Logo

NETGEAR FS728TPv2 User Manual

NETGEAR FS728TPv2
261 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #227 background imageLoading...
Page #227 background image
Chapter 7: Maintenance | 227
FS728TP Smart Switch Software Administration Manual
If successful, you will see “Reply From IP/Host: icmp_seq = 0. time = xx usec. Tx = x,
Rx
= x Min/Max/Avg RTT = x/x/x msec.”
If a reply to the ping is not received, you will see “Reply From IP/Host: Destination
Unreachable. Tx = x, Rx = 0 Min/Max/Avg RTT = 0/0/0 msec”.
Traceroute
Use the Traceroute utility to discover the paths that a packet takes to a remote destination.
To display this page, click Maintenance Troubleshooting Traceroute.
To configure the Traceroute settings and send probe packets to discover the route to a host
on the network:
1. In the Hostname/IP Address field, specify the IP address or the hostname of the
station you want the switch to ping. The initial value is blank. This information is not
retained across a power cycle.
2. Optionally, configure the following settings:
Probes Per Hop. Specify the number of times each hop should be probed. The valid
range is 1–10.
MaxTTL. Specify the maximum time-to-live for a packet in number of hops. The valid
range is 1–255.
InitTTL. Specify the initial time-to-live for a packet in number of hops. The valid range
is 0– 255.
MaxFail. Specify the maximum number of failures allowed in the session. The valid
range is 0–255.
Interval. Specify the time between probes in seconds. The valid range is 1–60.

Table of Contents

Other manuals for NETGEAR FS728TPv2

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the NETGEAR FS728TPv2 and is the answer not in the manual?

NETGEAR FS728TPv2 Specifications

General IconGeneral
BrandNETGEAR
ModelFS728TPv2
CategorySwitch
LanguageEnglish

Related product manuals