Replace a Fan on a ReadyNAS 4360
The four fans near the middle of the RR4360 system are hot-swappable.
To replace a fan on a ReadyNAS 4360 storage system:
1. Remove the chassis cover.
For more information, see Access the Inside of the Storage System on page 98.
2.
Pull up on the fan gently to remove it from the housing.
3.
Insert the replacement fan into the housing.
4.
Make sure that the four bumpers fit in their grooves.
5.
Push the fan down to seat the fan and the fan power connections.
If the system power is on, the hot-plug feature causes the fan to start immediately.
Replace the On-Board Battery
Replace the battery only with the same or an equivalent type recommended by
NETGEAR. Dispose of used batteries according to the manufacturer's instructions.
Danger: Installing the on-board battery upside down, which reverses its polarities,
creates a risk of explosion. Take care to install the battery correctly.