7 Technical data
BU 0800 en-4521 131
7 Technical data
7.1 General frequency inverter data
Function Specification
3.0 … 16.0 kHz, factory setting = 6 kHz
Power reduction > 6 kHz for 400 V devices
Typical overload capacity
150% for 60 s, 200% for 3.5 s
Frequency inverter efficiency
IE2, 7.2 "Technical data for determining the energy efficiency level"
Operating / ambient temperature
-30 °C … +40 °C (S1 - 100 % ED), -30 °C … +50 °C (S3 - 70 % ED)
For detailed information (including UL values) on individual device types and
operating modes, see 7.2.1 "Electrical data 3~400 V"
Storage and transport temperature
9.1 "Maintenance information"
IP55 (without painting), IP66 (with painting)
Max. installation altitude above sea
level
No power reduction, overvoltage category 3
1% / 100 m power reduction, overvoltage category 3
1% / 100 m power reduction, overvoltage category 2, external
overvoltage protection required at mains input
Transport (IEC 60721-3-2:)
Operation (IEC 60721-3-3):
1.7 "Standards and approvals", siehe P219
2.6.5 "Electrical connection of power unit"
Protective measures against
Overtemperature of the frequency inverter
Overvoltage and undervoltage
Short circuit, earth fault,
overload
Motor temperature monitoring
I
2
t motor, PTC/bimetallic switch
Sensorless current vector control (ISD), linear V/f characteristic curve, VFC
open-loop, CFC open-loop, CFC closed-loop
Waiting period between two mains
switch-on cycles
60 s for all devices in normal operating cycle
RS485 (USS) (for parameterisation units only)
RS232 (single slave)
Bluetooth via NORDAC ACCESS BT