8 Additional information
BU 0800 en-4521 145
I
Setpoint source and
setpoint selection
II
Signal processing
and ramp
III
Control and motor
model (slip
determination)
8.6 Definition of set and actual value processing (frequencies)
The frequencies used in parameter P543 are processed in various ways according to the following
table.
Func. Name Meaning
Output to ... Withou
t
left/rig
ht
With slip
I II III
8 Set point frequency Set point frequency from
setpoint source
X
1 Actual frequency Set point frequency before motor
model
X
23 Act. freq. With slip Actual frequency on the motor X X
19 Freq. Master Value Set point frequency from
setpoint source
Master value
(freed from enable direction)
X X
20 Set Freq. After
Ramp
Set point frequency before motor
model
Master value
(freed from enable direction)
X X
24 Lead.act.freq.+slip Actual frequency on the motor
Master value
(freed from enable direction)
X X X
21 Act. Freq. w/o Slip Actual frequency without slip
Master value
X
Table 8: Set and actual value processing in the frequency inverter