3 Display
BU 0800 en-4521 45
3.1.3 Display of M1 and M2 when using PROFINET
LED Labelling Display Meaning
(Link activity)
Connection is established, data is being transmitted
Connection is established, no data transmission
MS
RUN = Ethernet state
flashing (1 Hz)
DCP signal service is triggered via the bus
NS
BF = Ethernet Error
Faulty configuration (PROFInet)
On No configuration or no physical connection
(Link activity)
No configuration / no physical connection
3.1.4 Display M3
For devices from Size 2 onwards, the M3 LEDs indicate the level of the digital outputs. The meaning
of the display depends on whether the SK CU6-STO option is installed.
LED Labelling Display Meaning
DO1
DO2
Green On Digital output 2 = low
Display of M3 if SK CU6-STO (SK 3x1P) is installed
LED Labelling Display Meaning
M3-1
S-DIN1
Yellow On Safety input Dig.In = high
Safety input Dig.In = low
M3-2
S-DIN2
Safety input Dig.In = high
Safety input Dig.In = low