NORDAC ON / ON+ (SK 3xxP) – Manual with installation instructions
30 BU 0800 en-4521
2.6 Electrical Connection
Electric shock
Dangerous voltages may be present at the plug contacts for the power connections (e.g. mains cable,
motor cable) even when the device is not in operation.
• Before starting work, check that all relevant components (voltage source, connection cables) are
free of voltage using suitable measuring equipment.
• Use insulated tools (e.g. screwdrivers).
• Earth devices.
Electrical connections are made exclusively with plug connectors.
2.6.1 Mains connection
Power connection Connection Contact assignment
Mains input: 1 2 3
A B
1)
L1 L2 L3 PE 24 V GND
NORDAC ON X1
NORDAC ON+ X4
Wall mounting
NORDAC ON
NORDAC ON+
X4
L1 L2 L3 PE 24 V GND
NORDAC ON X2
NORDAC ON+ X5
NORDAC ON
NORDAC ON+
X5
1) NQ16 = MQ15 from Murr or XTEC15 from LQ Group
2.6.2 Daisy chain connection
Power connections provide the possibility of setting up a daisy chain. This way, the wiring effort for
devices close to each other can be reduced.